XSRING+ SHDSL switch _________________ User’s guide Document reference : 9018809-01 _________________
OVERVIEW Page 10 User’s guide ref 9018809-01 XSRING+ SHDSL switch 3.2 Redundancy solutions: RSTP and proprietary failsafe ring Industrial appli
OVERVIEW XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 11 3.3 The by-pass function When the network is a daisy chain – that case is ve
OVERVIEW Page 12 User’s guide ref 9018809-01 XSRING+ SHDSL switch 3.6 VLANs The XSRING features VLAN per port : Each Ethernet port can be assi
INSTALLATION Page 13 User’s guide ref 9018809-01 XSRING+ SHDSL switch 1 Dimensions 2 Connectors XSRING+2400 XSRING+2220 XSRIN
INSTALLATION Page 14 User’s guide ref 9018809-01 XSRING+ SHDSL switch XSRING+BP2400 XSRING+BP2220 XSRING+BP2230
INSTALLATION XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 15 Push-button : A push-button is located close to the DIP switches. It e
INSTALLATION Page 16 User’s guide ref 9018809-01 XSRING+ SHDSL switch 2 positions screw terminal : RS485 Position Signal Function 1 A RS485
INSTALLATION XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 17 3 Led indicators Led Status Description 1 ON green The supply voltage
INSTALLATION Page 18 User’s guide ref 9018809-01 XSRING+ SHDSL switch 4 DIN rail mounting Mounting the unit on the DIN rail This unit should
INSTALLATION XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 19 8 RS232 interface The RS232 data rate can be tuned from 1200 to 115200 b/s
The XSRING+ SHDSL switch is manufactured by ETIC TELECOM 13 Chemin du vieux chêne 38240 MEYLAN FRANCE TEL : + 33 4-76-04-20-00 FAX : + 3
INSTALLATION Page 20 User’s guide ref 9018809-01 XSRING+ SHDSL switch 11 Line cable Twisted pair The XSRING+ shdsl switch is designed to be co
INSTALLATION XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 21 12 Protecting the shdsl switch from lightning if the line is exposed to l
INSTALLATION Page 22 User’s guide ref 9018809-01 XSRING+ SHDSL switch 13 Connecting the shdsl switch to the line The SHDSL signal is not pol
INSTALLATION XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 23 13.3 By-pass function To enable the by-pass function, connect the line1 t
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 25 1 Set up steps To configure the XSRING, we advise to proceed as follows : •
SET UP Page 26 User’s guide ref 9018809-01 XSRING+ SHDSL switch 2 Connecting a PC to the XSRING+ for configuration 2.1 Overview Administration
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 27 2.3 Modifying the configuration from the LAN Launch the html browser and enter
SET UP Page 28 User’s guide ref 9018809-01 XSRING+ SHDSL switch 6 Recovering a free access to the administration server Press the push-button,
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 29 To enable the router function and assign an IP @ to the SHDSL interface of the XS
CONTENT XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 3 OVERVIEW 1 PRODUCTS IDENTIFICATION...
SET UP Page 30 User’s guide ref 9018809-01 XSRING+ SHDSL switch 9 SHDSL connection set up overview 9.1 Principle of operations The SHDSL switch
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 31 9.2 SHDSL connection profiles Auto STU-R profile : That connection profile has
SET UP Page 32 User’s guide ref 9018809-01 XSRING+ SHDSL switch 10 Setting up a multidrop or ring SHDSL connection This chapter describes how t
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 33 10.3 Step 2 : SHDSL test and set up adjustment • Connect the two XSRING+ to th
SET UP Page 34 User’s guide ref 9018809-01 XSRING+ SHDSL switch 11 Setting up a point to point connection using 2 twisted pairs This chapter de
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 35
SET UP Page 36 User’s guide ref 9018809-01 XSRING+ SHDSL switch Setting up the XSRING+ number 2 • Click Set up > Ethernet & switching &g
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 37 • Check the quality of each SHDSL port : The SNR ratio margin must be 2 / 4 or
SET UP Page 38 User’s guide ref 9018809-01 XSRING+ SHDSL switch 12 RSTP redundancy protocol • Select “Set-up > Ethernet & switching >
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 39 “Edge port” parameter : An Edge port is a port located on the border of the ne
CONTENT Page 4 User’s guide ref 9018809-01 XSRING+ SHDSL switch CONFIGURATION 1 SET UP STEPS...
SET UP Page 40 User’s guide ref 9018809-01 XSRING+ SHDSL switch 14 VLAN 14.1 Overview VLAN function The VLAN technology conform to the IEEE 80
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 41 14.2 Set up Attention : Before saving the VLAN configuration, make sure you
SET UP Page 42 User’s guide ref 9018809-01 XSRING+ SHDSL switch 14.2.1 Egress policy set up That part of the page is made to register the VLAN I
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 43 To set up the Egress policy • Select “Set up > Ethernet & switching >
SET UP Page 44 User’s guide ref 9018809-01 XSRING+ SHDSL switch 14.2.2 Ingress policy set up That part of the page is made to register which pro
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 45 To set up the Ingress policy • Select “Set up > Ethernet & switching >
SET UP Page 46 User’s guide ref 9018809-01 XSRING+ SHDSL switch 14.3 Html server and serial gateway When VLAN management is enabled, the admini
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 47 15 SNMP 15.1 Overview The XSRING+ supports the following MIBS : • RFC1213-MI
SET UP Page 48 User’s guide ref 9018809-01 XSRING+ SHDSL switch 15.3 Setting up the SNMP traps To enable the SNMP traps, • Select “Set up >
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 49 16 Quality of service (QoS) 16.1 DiffServ benefits & overview The goal of
CONTENT XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 5 … CONFIGURATION 17 SERIAL GATEWAY ...
SET UP Page 50 User’s guide ref 9018809-01 XSRING+ SHDSL switch An example is given hereafter : Minimum bandwidth Maximum bandwidth % of th
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 51 Step 3 : Define the classes • Select the QoS menu. Assign a minimum and a maxi
SET UP Page 52 User’s guide ref 9018809-01 XSRING+ SHDSL switch 17 Serial gateway The XSRING+2220 or BP2220 feature 1 RS232 and 1 RS485 – 2 wir
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 53 17.1 Modbus gateway The ETIC modbus gateway is made to link modbus devices conne
SET UP Page 54 User’s guide ref 9018809-01 XSRING+ SHDSL switch “Activate Proxi cache” parameter : Enable the proxi option if you wish to avoid t
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 55 17.1.2 “Modbus client” gateway That gateway can be used only if a serial modbus
SET UP Page 56 User’s guide ref 9018809-01 XSRING+ SHDSL switch 17.2 RAW TCP gateway 17.2.1 Raw client gateway The RAW client gateway can be u
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 57 17.2.2 Raw server gateway That gateway can be used if a serial slave device has
SET UP Page 58 User’s guide ref 9018809-01 XSRING+ SHDSL switch 17.3 RAW UDP gateway 17.3.1 Overview The RAW UDP gateway enables you to connec
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 59 17.4 Multicast gateway Internet Protocol multicast is a bandwidth-conserving t
OVERVIEW Page 6 User’s guide ref 9018809-01 XSRING+ SHDSL switch 1 Products identification Switch SHDSL XSRING+ XSRING+2400 2220 2230 BP24
SET UP Page 60 User’s guide ref 9018809-01 XSRING+ SHDSL switch • Select the “transparent” and then the “multicast” menus. • Enable the multi
SET UP XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 61
MAINTENANCE & DIAGNOSTIC XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 63 1 Diagnostic menu Select the Diagnostic menu and then th
MAINTENANCE & DIAGNOSTIC Page 64 User’s guide ref 9018809-01 XSRING+ SHDSL switch 1.3.2 SHDSL counters That page is divided in two parts; it
MAINTENANCE & DIAGNOSTIC XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 65 2 Storing the configuration to a file Once a product has
MAINTENANCE & DIAGNOSTIC Page 66 User’s guide ref 9018809-01 XSRING+ SHDSL switch 4 Updating the firmware • Select “Maintenance > Firmwa
APPENDIX DATA RATE VERSUS DISTANCE XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 67 Maximum distance between 2 switches vers
APPENDIX 2 HTML server XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 69 Set up Ethernet & switching SHDSL ports To configure th
OVERVIEW XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 7
APPENDIX 2 HTML server Page 70 User’s guide ref 9018809-01 XSRING+ SHDSL switch Maintenance Configuration management To save or restore the c
APPENDIX 2 HTML server XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 71
13, Chemin du Vieux Chêne 38240 Meylan France Tel : 33 4 76 04 20 00 Fax : 33 4 76 04 20 01 E-mail : contact@eticte
OVERVIEW Page 8 User’s guide ref 9018809-01 XSRING+ SHDSL switch 2 Data-sheet Dimensions 137 x 48 x 116 mm (h, l, d) C.E.M EN50082-2 Electric
OVERVIEW XSRING+ SHDSL switch User’s guide ref 9018809-01 Page 9 3 Product overview 3.1 Function The XSRING+ provides two SHDSL interfaces to
Kommentare zu diesen Handbüchern