CONFIGURATION
Page 82 User guide ref. 9015909-03 Industrial router IPL-E
19 Serial to IP gateway
The IPL-E features two serial ports.
A serial gateway can be assigned to each port .
If the same type of gateway is assigned to both serial ports, the UDP or
TCP port numbers must be different.
The gateways listed below are provided :
Modbus client or server (i.e. master or slave)
To connect several serial modbus slaves to several IP modbus clients.
Or to connect a serial modbus master to an IP modbus server.
RAW TCP server or client :
To connect 2 serial devices through an IP network.
Telnet :
To connect a Telnet terminal to the RAS.
RAW UDP :
To exchange serial data between several serial and IP devices, through an
IP network, using a table of IP addresses..
Unitelway slave :
To connect a serial unitelway master to an IP network.