CONFIGURATION
Page 86 User guide ref. 9015909-03 Industrial router IPL-E
“TCP port number” parameter
:
Set the TCP port number the gateway has to use.
“IP address” parameter
:
The modbus client gateway allows to transmit modbus requests from the
serial modbus master device to any modbus slave device, more precisely
called “ modbus server”, located on the IP network.
To assign an IP address to each modbus slave device with which the
serial master device needs to communicate, click the “add a link” button;
Assign an IP address in front of each modbus slave address with which
the serial master device will have to communicate.
19.2 RAW TCP gateway
19.2.1 Raw client gateway
The RAW client gateway can be used if a serial “master” device has to
send requests to one slave device (also called server) located on the IP
network.
The server can be either an ETIC gateway or a PC including a software
TCP server.
Select the “transparent” and then the “raw client COM1” or the “raw
client COM2” menu .
Enable the raw client gateway; and set up the parameters as follows :