INSTALLATION
XSLAN SHDSL switch User’s guide ref 9014709-02 Page 15
1.3 DIP switches and push-button
DIP switches
SW 1 SW 2
Management
OFF OFF
The current IP@ of the product is the stored IP @
ON OFF
The active IP@ of the product is the factory IP@ : 192.168.0.128
No login and password are required to access to the html server
OFF ON
The active IP@ is provided by the BOOTP or DHCP server
ON ON
No IP @ is assigned to the product; DIP switch configuration
SW 3 SW 4 SW 5
Shdsl port 1
OFF OFF OFF
NTU mode
OFF OFF ON
LTU mode - Auto
OFF ON OFF
LTU mode – 2304 kbit/s
OFF ON ON
LTU Mode – 2048 kbit/s
ON OFF OFF
LTU Mode – 1536 kbit/s
ON OFF ON
LTU Mode – 1024 kbit/s
ON ON OFF
LTU Mode – 512 kbit/s
ON ON ON
LTU Mode – 256 kbit/s
SW 6 to SW 12
Not used - Must be left OFF
Push-button :
A push-button is located close to the DIP switches.
It enables to restore the factory profile.
To restore the factory profile, switch the power on while pressing the
push-button until the OPERATION led turns green.
Attention : Once the factory profile has been restored, the stored
configuration is lost.