HTML SET UP & DIAGNOSTIC
XSLAN SHDSL switch User’s guide ref 9014709-02 Page 43
15 SNMP set up
The XSLAN is compliant with the MIB2.
The SNMP manager can acquire the status (Connected or not connected)
of each SHDSL port.
The XSLAN is also able to send SNMP traps
when each SHDSL connection is established.
or when each SHDSL connection is disconnected.
To enable the SNMP traps function,
Select the “Alarm” menu and then the “SNMP” menu :
Select the “Activation” checkbox.
Enter the IP address of the management system.
Enter the Sysname value (for instance XSLAN).
Enter the Syslocation value (for instance the label of the site where
the XSLAN is installed).
Enable the traps related to the different events :
Product startup
SHDSL connection
SHDSL disconnection